Technical specifications
TopMessage/TopLab
TopMessage : Dimensions and signal connections
Housing (W x H x D – 200 x 73 x 118 mm)
Rail mounting DIN EN 50023 or screw fixing, weight app. 1kg
Detachable screw terminals , 33 terminals in 2 rows, lead
protection, connecting cabling max. 2.5 mm²
TopLab: Dimensions and signal connections
Housing (W x H x D – 226 x 145 x 180 mm)
up to sixty-four 4 mm laboratory connectors, gold plated
Power supply
12-36 VDC / 12-28 VACeff. / ± 10%,
for AMDT 18 VAC/DC
Power input for master device: < 10 Watt
TopLab is supplied with wall power supply connection
Temperature range
Operational: -20 to +60°C
LC Display
For servicing purposes: 4 rows à 15 characters
4-keys for cursor, enter, esc, and reset
Displays: Configuration data, channel name, scaled and
lineared measurement data
Ethernet interface
Physical equipment:
RJ45 (8-pol. STP-socket), 10 Base-T (twisted pair, 10
Mbps, half-duplex), galvanic isolation: 1 kV
Protocols: TCP/IP, UDP, ICMP
Data storage
Storage partitionable, data compression
Standard: 500 kB; max. 96,000 measurement values
Maximum: 1 GB; 128 million measurement values
Serial interfaces
COM 1: RS232/485 interfaces
Physical equipment: 9-pol. Sub-D socket, DIN EN
ISO 19245-1, switchable interface: RS232/485/422
Baud rate: RS232: 125 kBaud
Baud rate: RS485: 6 Mbaud
Galvanic isolation: 1 kV
Protocols: TCP/IP, user-defined for connection of
modems, PC-terminals, displays, ModBus RTU
COM 2: RS232/485 interfaces
Physical equipment: 9-pol, Sub-D socket, DIN 41652,
Part 1 (ISO 4902), switchable interface: RS232/485/422
Baud rate: RS232: 125 kBaud
Baud rate: RS485: 6 Mbaud
Galvanic isolation: 1 kV
Protocols: TCP/IP, user-defined for connection of
modems, PC-terminals, large displays, ModBus RTU
COM1: ProfiBus DP slave interface
Modulbus
Physical equipment: 2-pol. Phoenix plug-in device
Internal bus for the connection of other modules
Galvanic isolation: 1 kV
Baud rate: 1 MBaud (adjustable)
Length: up to10 m (1 Mbaud)
Analog inputs
Voltage range: ± 156 mV bis ± 10 V / ± 110 V
Current range: 0/4 ... 20 mA
(max. 500 Ω Shunt)
Thermocouples: all types,
Integrated temperature compensation
Resistance thermometer RTD, NTC und linear
resistors up to 10 kΩ (not ADVT)
Resolution:
24 bit maximum
Potential isolation
Resolution
24 Bit (≈7 decimal places)
Measurement accuracy: V, mA 0.01 % of accumulated
value
RTD 0.1 K and RTD 100
Thermocouple 0.1% of accumulated value
V (ADGT: 110 V MB) 0.06 % of accumulated value
Analog outputs
Resolution: 16 Bit
Potential isolation: 750 V
Output signal: 0/4 ... 20 mA
Maximum burden: 650 Ω
Digital inputs
Potential isolation: 2,5 kV
LOW: 0 .. 1,5 ,5 mA
HIGH: 3 .. 90 mA
Protected against polarity reversal
Frequency / counter inputs
Potential isolation: 2,5 kV
LOW: 0 .. 1,5 ,5 mA
HIGH: 3,5 .. 90 mA
Protected against polarity reversal
Measurement frequency up to 30 kHz at TTL-level
Digital outputs
Potential isolation 2,5 kV
switching voltage max. 50 ,5 A
Integrated inverse diode
Les séries E3N de Chauvin Arnoux sont des pinces pour les mesures de courant AC/DC. Elle sont conçues pour mesurer les courants alternatifs et DC en utilisant la technologie par effet Hall. Leur forme étroite et allongée les rendent idéales pour les mesures dans des faisceaux de câbles ou dans des espaces confinés tels que le câblage sur les panneaux de commande, les unités de commande de moteur et les circuits électriques sur les véhicules à moteur. Elle est particulièrement appréciée pour ses vraies mesures RMS sur les signaux AC et DC. Elle offre deux sensibilité différentes. Ces pinces sont approuvées IEC 1010-1, la IEC 1010-2-032, degré de pollution 2, norme EN 50081-1: classe B, EN 50082-2, IEC 1000-4-2, IEC 1000-4-4 et IEC 1000-4-8
Courant de 10A nominal et 100A crête
Tension de sortie de 100 mV/A et 10 mV/A
La bande passante à -3dB est de DC à 100KHz (selon la valeur du courant)
Temps de montée/ descente de 3 µs (10A) et 4µs (100A)
Capacité auto-extinguible UL94 V2
Couleur gris foncé
Gamme de température d'utilisation 0°C à + 50°C
Boîtier de protection IP20 (IEC 529)
L'impédance d'insertion est inférieure à 1.3mohm/10mohm à 10KHz/50KHz